Quintiq file version 2.0 
 | 
#parent: #root 
 | 
Method MPSyncPISPSpecification_MP ( 
 | 
  Boolean isoverwitemanualconfig, 
 | 
  IOPISPSpecifications iopispspecifications 
 | 
) 
 | 
{ 
 | 
  Description: 'Synchronization of PISP Specification for MPSync' 
 | 
  TextBody: 
 | 
  [* 
 | 
    // Select a set of existing PISPSpecification 
 | 
    existing := selectset( this, PISPSpecification, item, true ); 
 | 
    updates := construct( PISPSpecifications ); 
 | 
     
 | 
    // Traverse the new set of valid PISPSpecification 
 | 
    traverse( iopispspecifications , Elements, io, io.IsValid() ) 
 | 
    { 
 | 
      // Find existing PISPSpecification 
 | 
      objectinstance := PISPSpecification::FindPISPSpecificationTypeIndex( io.ProductID(), io.StockingPointID() ); 
 | 
      // Find existing Product_MP 
 | 
      product := Product_MP::FindProductTypeIndex( io.ProductID() ); 
 | 
      // Find existing StockingPoint_MP 
 | 
      sp := StockingPoint_MP::FindStockingPointTypeIndex( io.StockingPointID() ); 
 | 
       
 | 
      // If no existing PISPSpecification is found, and there's valid Product_MP and StockingPoint_MP, create one 
 | 
      if( not ( isnull( product ) or isnull( sp ) ) ) 
 | 
      { 
 | 
        if( isnull( objectinstance ) ) 
 | 
        { 
 | 
          objectinstance := PISPSpecification::Create( product, 
 | 
                                                       sp, 
 | 
                                                       io.HasUserUnitOfMeasurement(), 
 | 
                                                       io.UnitOfMeasurementName(), 
 | 
                                                       io.IsNegativeInventoryAllowed(), 
 | 
                                                       io.IsExcluded(), 
 | 
                                                       io.IsExcludedFromBalancing(), 
 | 
                                                       io.IsSafetyStockKept(), 
 | 
                                                       io.InputLotSize(), 
 | 
                                                       io.IsExcludeShelfLifeAndMaturation(), 
 | 
                                                       true ); 
 | 
        } 
 | 
        // Else if the PISPSpecification is not manually configured or the imported instance should overwrite manual configuration, 
 | 
        // update the existing PISPSpecification 
 | 
        else if( not objectinstance.IsManuallyConfigured() or isoverwitemanualconfig ) 
 | 
        { 
 | 
          // Update PISPSpecification 
 | 
          objectinstance.Update( io.HasUserUnitOfMeasurement(), 
 | 
                                 io.UnitOfMeasurementName(), 
 | 
                                 io.IsNegativeInventoryAllowed(), 
 | 
                                 io.IsExcluded(), 
 | 
                                 io.IsExcludedFromBalancing(), 
 | 
                                 io.IsSafetyStockKept(), 
 | 
                                 io.InputLotSize(), 
 | 
                                 io.IsExcludeShelfLifeAndMaturation(), 
 | 
                                 true ); 
 | 
          updates.Add( objectinstance ); 
 | 
        } 
 | 
         
 | 
        if( not isnull( objectinstance ) ) 
 | 
        { 
 | 
          objectinstance.CustomUpdate( io, isoverwitemanualconfig );   
 | 
        } 
 | 
      } 
 | 
    } 
 | 
     
 | 
    // Get the set of old PISPSpecification to be deleted 
 | 
    tobedeleteset := existing.Difference( updates ); 
 | 
     
 | 
    // Traverse the set of PISPSpecification to be deleted 
 | 
    // Only delete PISPSpecification that is not manually configured or the imported instance should overwrite manual configuration 
 | 
    traverse( tobedeleteset, Elements, ele, 
 | 
              not ele.IsManuallyConfigured() or isoverwitemanualconfig ) 
 | 
    { 
 | 
      ele.Delete(); 
 | 
    } 
 | 
  *] 
 | 
} 
 |