1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
  | Quintiq file version 2.0 
 |  #parent: #root 
 |  StaticMethod Update ( 
 |    TransportCapacitys transportcapacities, 
 |    Unit owner, 
 |    DateTime start, 
 |    String timeunit, 
 |    Boolean isbatcheditlotsize, 
 |    Real lotsize, 
 |    Boolean isbatcheditcapacity, 
 |    Real mincapacity, 
 |    Real maxcapacity, 
 |    Boolean isbatcheditsecondarycapacity, 
 |    Boolean hassecondarycapacity, 
 |    Real secondarylotsize, 
 |    Real secondarymaxcapacity, 
 |    Real secondarymincapacity, 
 |    String secondaryuom 
 |  ) 
 |  { 
 |    Description: 'Batch edit transport capacity, from UI.' 
 |    TextBody: 
 |    [* 
 |      traverse( transportcapacities, Elements, tc ) 
 |      { 
 |        // Case related to batch edit. 
 |        if( transportcapacities.Size() > 1 ) 
 |        { 
 |          // The selectors are disabled if batch edit. So, it is incorrect to take the input from UI. 
 |          owner := tc.Unit(); 
 |          start := tc.Start(); 
 |       
 |          // Get back the unit capacity value if the batch edit check boxes are not checked, instead of from UI. 
 |          if( not isbatcheditcapacity ) 
 |          { 
 |            timeunit := tc.TimeUnit(); 
 |            mincapacity := tc.MinimumCapacity(); 
 |            maxcapacity := tc.MaximumCapacity(); 
 |          } 
 |       
 |          if( not isbatcheditlotsize ) 
 |          { 
 |            lotsize := tc.LotSize(); 
 |          } 
 |           
 |          if( not isbatcheditsecondarycapacity ) 
 |          { 
 |            hassecondarycapacity := tc.HasSecondaryCapacity(); 
 |            secondarylotsize     := tc.SecondaryLotSize(); 
 |            secondarymaxcapacity := tc.SecondaryMaximumCapacity();  
 |            secondarymincapacity := tc.SecondaryMinimumCapacity(); 
 |            secondaryuom         := tc.SecondaryUnitOfMeasureName(); 
 |          } 
 |        } 
 |       
 |        tc.Update( owner, 
 |                   start, 
 |                   timeunit, 
 |                   mincapacity, 
 |                   maxcapacity, 
 |                   lotsize, 
 |                   hassecondarycapacity, 
 |                   secondarylotsize, 
 |                   secondarymaxcapacity, 
 |                   secondarymincapacity, 
 |                   secondaryuom, 
 |                   false ); // Action from UI will count as manual config, e.g. not from db 
 |       
 |      } 
 |    *] 
 |  } 
 |  
  |