Quintiq file version 2.0
|
#parent: #root
|
StaticMethod ValidateInput (
|
output String feedback_o,
|
output String sanitycheckfeedback_o,
|
StockingPoint_MP stockingpoint,
|
Date start,
|
Real maxcapacity,
|
StockingPointCapacity stockingpointcapacity,
|
Boolean checkunique
|
) declarative remote as Boolean
|
{
|
Description: 'Check for input obtained from UI'
|
TextBody:
|
[*
|
// Validate input from UI
|
feedback_o := '';
|
sanitycheckfeedback_o := '';
|
gp := guard( stockingpoint.MacroPlan().GlobalParameters_MP(), null( GlobalParameters_MP ) );
|
|
// Check if the primary keys is unique
|
if( checkunique
|
and not StockingPointCapacity::IsPrimaryKeysUnique( stockingpoint, start, stockingpointcapacity ) )
|
{
|
feedback_o := Translations::MP_StockingPointCapacity_ValidateInput_IsNotUnique();
|
sanitycheckfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue();
|
}
|
// Check if max capacity is less than zero
|
else if( maxcapacity < 0.0 )
|
{
|
feedback_o := Translations::MP_StockingPointCapacity_ValidateInput_IsNegativeMaxCapacity( maxcapacity );
|
sanitycheckfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue();
|
}
|
// Check if max capacity is within the allowed range
|
else if( maxcapacity <> 0
|
and not GlobalParameters_MP::GetIsValueWithinRange( maxcapacity,
|
gp.AbsoluteUpperLimit(),
|
gp.AbsoluteLowerLimit() ) )
|
{
|
feedback_o := Translations::MP_StockingPointCapacity_ValidateInput_InvalidMaxCapacity( maxcapacity,
|
gp.AbsoluteUpperLimit(),
|
gp.AbsoluteLowerLimit() );
|
sanitycheckfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue();
|
}
|
// Check if stocking point is null
|
else if( isnull( stockingpoint ) )
|
{
|
feedback_o := Translations::MP_StockingPointCapacity_ValidateInput_IsNullStockingPoint();
|
sanitycheckfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataWarning();
|
}
|
|
// Add instance text if any of the preconditions above are violated
|
if( feedback_o <> '' )
|
{
|
spname := MacroPlan::GetSubstituteName( guard( stockingpoint.Name(), '' ) );
|
feedback_o := SanityCheckMessage::GetFormattedMessage( Translations::MP_StockingPointCapacity_Instance( spname, start ),
|
feedback_o );
|
}
|
|
return feedback_o = '';
|
*]
|
}
|