| Quintiq file version 2.0 | 
| #parent: #root | 
| StaticMethod ValidateInput ( | 
|   output String feedback_o, | 
|   output String sanitychkfeedback_o, | 
|   MacroPlan macroplan, | 
|   Unit unit, | 
|   String name, | 
|   Boolean hasstart, | 
|   Date start, | 
|   Boolean hasend, | 
|   Date end, | 
|   Boolean hasuserlotsize, | 
|   Real userminimumquantity, | 
|   Boolean hasusermaximumquantity, | 
|   Real usermaximumquantity, | 
|   Real userlotsize, | 
|   Real co2Emission, | 
|   String processtype | 
| ) declarative remote as Boolean | 
| { | 
|   Description: 'Validate input, triggered when user create operation from the UI or edit it.' | 
|   TextBody: | 
|   [* | 
|     feedback_o := ''; | 
|     sanitychkfeedback_o := ''; | 
|     lengthlimit := GlobalParameters_MP::GetLengthOfNames(); | 
|      | 
|     // Check if unit is valid | 
|     if( isnull( unit ) ) | 
|     { | 
|       feedback_o := Translations::MP_Process_ValidateInput_IsNullUnit( processtype ); | 
|       sanitychkfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue(); | 
|     } | 
|     // Check if start and end window is valid | 
|     else if( hasend and hasstart and ( start >= end ) ) | 
|     { | 
|       feedback_o := Translations::MP_Process_ValidateInput_IsStartDateAfterEndDate( end, start ); | 
|       sanitychkfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue(); | 
|     } | 
|     // Transport unit cannot be used for operation | 
|     else if( processtype = Operation::GetDefinitionName() | 
|              and unit.HasCapacityTypeTransportBase() ) | 
|     { | 
|       feedback_o := Translations::MP_Process_ValidateInput_IsNotTransportUnit(); | 
|       sanitychkfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataIssue(); | 
|     } | 
|     // if has user lot size, check the remaining | 
|     else if( not Process_MP::ValidateInputLotSize( feedback_o, sanitychkfeedback_o, hasuserlotsize, userminimumquantity, hasusermaximumquantity, usermaximumquantity, userlotsize ) ) | 
|     { | 
|     } | 
|     // name should not be blank and name length should not be more than length limit | 
|     else if( name = '' or name.Length() > lengthlimit ) | 
|     { | 
|       feedback_o := Translations::MP_Process_ValidateInput_IsNameEmpty( lengthlimit, processtype ); | 
|       sanitychkfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataWarning(); | 
|     } | 
|     // co2 emission should >= 0 | 
|     else if( not Process_MP::HasValidCO2( co2Emission, feedback_o ) ) | 
|     { | 
|       sanitychkfeedback_o := SanityCheckCategoryLevel::GetSanityCheckCategoryDataWarning(); | 
|     } | 
|      | 
|      | 
|     // Add feedback text is any of the preconditions above are violated | 
|     if( feedback_o <> '' ) | 
|     { | 
|       processname := MacroPlan::GetSubstituteName( name ); | 
|       // add instance text | 
|       msg := SanityCheckMessage::GetFormattedMessage( Translations::MP_Process_Instance( processtype, processname ), | 
|                                                       feedback_o ); | 
|       feedback_o := msg;                                                    | 
|     } | 
|      | 
|     return feedback_o = ''; | 
|   *] | 
| } |